Three Phase Electric

Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob

Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob
Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob

Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob

PLEASE READ STORE DETAILS CAREFULLY! FLUKE 1734/EUS THREE PHASE POWER MEASUREMENT ENERGY LOGGER WITH 3 X 1500A 12INCH IFLEX CURRENT PROBES AND FLUKE CONNECT.

Product overview: Fluke 1732 and 1734 Three Phase Power Measurement Logger. Three phase power measurements made easy. The Fluke 1732 (without wifi) and 1734 (with wifi) Three Phase Electrical Energy Loggers deliver easy to use three phase power measurement data for discovering sources of electrical energy waste, overloaded circuits and help you perform routine load studies. Discover when and where energy in your facility is being consumed - from the service entrance to individual circuits. Access and share three phase power data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins.

Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill. Key measurements: Automatically capture and log voltage, current, power, power factor, energy and associated values. Fluke Connect® compatible: View data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities WiFi infrastructure. Convenient instrument powering: Power instrument directly from the measured circuit. Measure all three phases: With included 3 flexible current probes. Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis. Optimized user interface: Quick, guided, graphical setup ensures youre capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty. Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display. Complete in-the-field setup through the front panel: No need to return to the workshop for download and setup or to take a computer to the electrical panel. Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module. Energy Analyze Plus application software: Download and analyze every detail of energy consumption with our automated reporting.

Which three-phase logger is right for you? Neutral Current, 4th current channel. PQ Health Graphical overview (EN50160). Fully integrated logging with Fluke Connect®.

Requires FREE software license available upon product registration. Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale). ±(0.2% + 0.01%).

±(1% + 0.02%). ±(1% + 0.03%).

±(1.5% + 0.03%). ±(0.7% + 0.02%). 42.5 Hz to 69 Hz. ±(0.2% + 0.02%). ±(1% + 0.1%). ±(5% + 0.2%). Intrinsic Uncertainty ±(% of reading +% of range)¹. 150 A / 1500 A. 300 A / 3000 A. 600 A / 6000 A. 4 A / 40 A. 1.2% + 0.005%. 1.2% + 0.0075%. 1.7% + 0.0075%. 2.5% of measured apparent power. Additional uncertainty in% of range¹.

¹Range = 1000 V x Irange Reference conditions. Environmental: 23 °C ±5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH. Input conditions: Cos/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%. Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10% of Irange. Primary conductor of clamps or Rogowski coil in center position.

Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C. 100 V to 500 V using safety plug input when powering from the measurement circuit. 100 V to 240 V using standard power cord (IEC 60320 C7). 15 VA when powered using IEC 60320 input.

68.2% (in accordance with energy efficiency regulations). Li-ion 3.7 V, 9.25 Wh, customer-replaceable. Four hours in standard operating mode, up to 5.5 hours in power saving mode. 10.24 kHz at 50/60 Hz, synchronized to mains frequency. 50/60 Hz (42.5 to 69 Hz).

1-, 1- IT, Split phase, 3- delta, 3- wye, 3- wye IT, 3- wye balanced, 3- Aron/Blondel (2-element delta), 3- delta open leg, Currents only (load studies). Internal flash memory (not user replaceable).

Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹. ¹The number of possible logging sessions and logging period depends on user requirements. Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy. User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min. Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms.

Demand Interval (Energy Meter Mode). Energy (Wh, varh, VAh), PF, maximum demand, cost of energy. User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off. File transfer via USB flash drive, firmware updates Max. File transfer and remote control via direct connection or WiFi infrastructure.

Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option). Data download device to PC. 4 (3 phases and neutral). 1000 Vrms, CF 1.7. 42.5 Hz - 3.5 kHz.

1000 V CAT III/600 V CAT IV. 3, mode selected automatically for attached sensor. Clamp input: 500 mVrms/50 mVrms; CF 2.8.

150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range. 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12. 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24. 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36. 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL.

0 to ±10 V dc, 1reading/s. Format: mx + b (gain and offset) user configurable. User configurable (7 characters, for example, °C, psi, or m/s). 10 °C to +50 °C (14 °F to 122 °F).

20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F). 10 °C to 30 °C (50 °F to 86 °F) max. 30 °C to 40 °C (86 °F to 104 °F) max. 40 °C to 50 °C (104 °F to 122 °F) max. 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV).

IP50 in accordance with EN60529. MIL-T-28800E, Type 3, Class III, Style B. IEC Mains Input: Overvoltage Category II, Pollution Degree 2. Voltage Terminals: Overvoltage Category IV, Pollution Degree 2. IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V.

EN 61326-1: Industrial CISPR 11: Group 1, Class A. Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment). USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. 0.1 x accuracy specification/°C. 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel. Instrument and power supply: Two-years (battery not included).

Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 in). Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 in). Instrument with power supply attached: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 in). Instrument: 1.1 kg (2.5 lb).

Power supply: 400 g (0.9 lb). I17xx-flex 1500 12 Flexible Current Probe Specifications. 1 to 150 A ac/10 to 1500 A ac. Intrinsic error at reference condition. ±(1% of reading + 0.02% of range).

Temperature coefficient over operating temperature range. 0.05% of reading/°C 0.09% of reading/°F.

1000 V CAT III, 600 V CAT IV. 7.5 mm (0.3 in).

38 mm (1.5 in). 2 m (6.6 ft). 20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F). 40 °C to +80 °C (-40 °F to 176 °F). Environmental: 23 °C ±5 °C, no external electrical/magnetic field, RH 65%.

Primary conductor in center position. 12 in 1,500A flexible current probe (3x). We are extremely busy, so we might not answer your emails. Items will be replaced or exchanged in case of DOA. All packages will go out after the weekend or after the holidays. The item "FLUKE 1734/EUS THREE PHASE POWER MEASUREMENT ELECTRICAL ENERGY LOGGER IFLEX PROB" is in sale since Wednesday, September 22, 2021.

This item is in the category "Business & Industrial\Light Equipment & Tools\Electrical Tools\Electrical Tool Kits". The seller is "computer_psycho" and is located in Van Nuys, California. This item can be shipped worldwide.

  • UPC: 095969801980
  • MPN: 1734
  • Brand: Fluke


Fluke 1734/eus Three Phase Power Measurement Electrical Energy Logger Iflex Prob